Deionized Filtration Equipment Water Treatment System Laboratory

Deionized Filtration Equipment Water Treatment System Laboratory

deionized filtration equipment water treatment system laboratory Using advanced reverse osmosis technology and ultra-pur
Basic Info
Model NO. OK-EP20
up Water Resistivity 18.25mohm-Cm at 25 Celsius Degree
Total Organic Carbon < 5 Ppb
Feed Water Requirements Tap Water,Pressure0.15-0.35MPa
Transport Package Standard Export Carton, 1set/Carton
Specification 410*300*500mm
Trademark Okay Energy
Origin Hunan, China
HS Code 2853001000
Production Capacity 200sets/Month
Product Description
deionized filtration equipment water treatment system laboratory
Using advanced reverse osmosis technology and ultra-purification column with original formula filler, Okay energy ultra-pure water and reverse osmosis RO pure water machine provides the overall solution of laboratory water. This series of machine use tap water as water. At the same time, the preparation of 18.2 MOhm-cm ultrapure water and RO pure water, ultrapure water reach or exceed the quality standards of China laboratory water and test methods(GB6682-2008)and ASTM, CLSI, ISO3696 level of water quality standards. This system is compact and easy to operate.

Deionized Filtration Equipment Water Treatment System Laboratory

Technical Parameter

Model

OK-EP10

OK-EP20

OK-EP40

OK-EP60

Output

10L/h

20L/h

40L/h

60L/h

Feed water requirements

Tap water,temperature 10~35ºC,pressure0.15-0.35Mpa ;

TDS:≤200mg/L

RO water quality

Conductivity(25ºC)

2-10μs/cm

Iron rejection rate

99%(new RO membrane)

Organic rejection rate

>99%,when MW>200Balton

Paeticles and bacteria rejection rate

>99%

Ultrapure water quality

Resistivity(25ºC)

18.2MOhm-cm

Total organic carbon TOC**

< 5 ppb

Particles(>0.2μm)

No particles larger than 0.22μm

Bateria

<1CFU/ml

Particle

>0.22um/ml<1um/ml

AC requirement

110/220V,50/60Hz

Dimension(L*W*H-mm)

410*300*500mm / 500*400*750mm

Weight(kgs)

20kgs,30kgs,50kgs,70kgs

Standard configuration

Main body,pressure tank

*The conductivity of RO water is affected by the inlet conductivity of tap water, and the typical value is calculated with inlet water less than 300 μS.

**The TOC value of water production is directly affected by inlet conditions and sampling operating environment.

Equipment technology

Pretreatment system → Reverse osmosis system → Middle water tank → Water pump → EDI device → Purification water tank → Pure water pump → UV sterilizer → Polishing mixed bed → 0.2 or 0.5μm precision filter → Product water

Deionized Filtration Equipment Water Treatment System Laboratory

Deionized Filtration Equipment Water Treatment System Laboratory

Deionized Filtration Equipment Water Treatment System Laboratory

Deionized Filtration Equipment Water Treatment System Laboratory


Related laboratory equipments